Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Full range AC 180-260V Input
2. Output 400/600W 12/24V 33/16A
3. 100% full load burn-in test
4. Protections: Short circuit / Overload / Over voltage / Over temperature
5. 12 months warranty
Model NO. | HY-400FA-12V | HY-400FA-24V | HY-400FAC-12V | HY-400FAC-24V | HY-400FA-II-12V | HY-400FA-II-24V | HY-400GB-24V | HY-400GB-12V | HY-600FA-12V | HY-600FA-24V |
Output Power | 400W | 400W | 400W | 400W | 400W | 400W | 400W | 400W | 600W | 600W |
Output Current | 33.3A | 16.6A | 33.3A | 16.7A | 33.3A | 16.6A | 16.6A | 33A | 50A | 25A |
Input Voltage | 12V | 24V | 12V | 24V | 12V | 24V | 24V | 12V | 12V | 24V |
Working temperature | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC | -20ºC-,50ºC |
Storage temperature | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC | -40ºC.85ºC |
Environmental humidity | 10%~95%RH | 10%~95%RH | 10%~95%RH | 10%~95%RH | 10%~95%RH | 10%~95% | 10%~95%RH | 10%~95%RH | 10%~95%RH | 10%~95%RH |
Size | 207*118*50mm | 179*109*51mm | 204*117*50mm | 217*118*50mm | ||||||
specifications | 40pcs/box | 40pcs/box | 40pcs/box | 30pcs/box |
Voltage Range | 176~264Vac200-380vdc | ||
Frequency Range | 47~63HZ | ||
Efficiency | 90% | ||
AC Current | 1.94A@220Vac | ||
Surge Current | 50A G220Vac Cold air dynamics | ||
Leakage Current | <0.75mA@220Vac | ||
Overload | 110%~150% of rated output power, protection mode; Hiccup mode, can be visually restored after removing abnormal conditions | ||
Over voltage | 110%~135% of rated output power, Protection mode; Hiccup mode, Can be visually restored after removing abnormal conditions | ||
Short circuit | Protection mode; Hiccup mode, can be visually restored after removing abnormal conditions,Can be short circuited for a long time | ||
operation temperature | -20ºC-,50ºC | ||
Operating Humidity | 20%~90%RH, No condensation | ||
Storage temperature ,humidity | -40ºC.85ºC,10%~95%RH, No condensation | ||
Seismic Resistance | 100~500Hz,3G 10mins/cycle,60 mins each for the X Y and Z axes | ||
Safety Standard,Protection Level | Complies with CE/FCC | ||
Voltage Resistance | In-Out :2KVac; input shell: 0.5KVac | ||
Insulation Resistance | In-Out,input shell,output shell:100M Ohms/500Vdc/25ºC/70%RH | ||
MIBF | >200K hrs.MIL-HDBK-217F(25ºC) | ||
package | carton case |
1. Professional rainproof design structure, multiple protection, not afraid of wind and rain.
2. lt adopts three-proof paint protection, which has superior insulation, moisture-proof, anti-leakage, dust.
proof, anti-corrosion, and other properties.
3. Built-in DC axial cooling fan, using low-noise motor, heat dissipation is efficient and silent.
4.Open cover wiring port, portable installation, and safety protection.
5. Adopt pure copper terminal posts, robust rust prevention, and avoid poor contact.
6. Multiple intelligent protection such as short circuits, overload, and overvoltage, safe and stable use.
7.Built-in LED indicator, one lamp shows the working status of the power supply.
Application:
Suitable for urban lighting projects, Wide input voltage range, steady and precise output voltage.Great power transformer for Led Lighting and CCTV Camera Security System, LED display screen, advertising sign lightbox, advertising logo, electronic advertising, communications & home appliance electronic equipment etc.
Item | Output | Item size | Weight | PC/CTNS | Input AC | ||||
5V | 12V | 24V | 30V | 36V | (MM) | (KG) | (PCS) | (V) | |
HY-400FB | 33.3A | 16.6A | 13.3A | 11.2A | 193*117*50 | 0.47 | 50 | 176~264V | |
HY-350FB | 70A | 193*117*50 | 0.49 | 50 | 176~264V | ||||
HY-400FA | 33.3A | 16.6A | 207*118*50 | 0.62 | 40 | 176~264V | |||
HY-400FAC | 33.3A | 16.7A | 207*118*50 | 0.62 | 40 | 176~264V | |||
HY-400FA-II | 33.3A | 16.7A | 179*109*51 | 0.54 | 40 | 176~264V | |||
HY-400GB | 33A | 16.6A | 204*117*50 | 0.47 | 40 | 176~264V | |||
HY-600FA | 50A | 25A | 217*118*50 | 0.85 | 30 | 176~264V | |||
HY-400FC | 33.3A | 16.6A | 191*117*50 | 0.42 | 50 | 176~264V | |||
HY-400FEC | 33.3A | 191*117*50 | 0.42 | 50 | 176~264V | ||||
HY-350FC | 70A | 191*117*50 | 0.42 | 50 | 176~264V | ||||
HY-400FC-II | 33.3A | 181*117*50 | 0.39 | 60 | 176~264V | ||||
HY-200FC | 16.7A | 166*94*50 | 0.32 | 60 | 176~264V | ||||
HY-150FC | 12A | 185*74*42 | 0.29 | 60 | 176~264V | ||||
HY-120FC | 10A | 145*74*42 | 0.23 | 80 | 176~264V | ||||
HY-60FC | 5A | 120*74*42 | 0.18 | 80 | 176~264V | ||||
HY-300TF | 25A | 191*117*50 | 0.42 | 60 | 176~264V | ||||
HY-300TBS | 25A | 191*117*50 | 0.42 | 60 | 176~264V | ||||
HY-300TBD | 25A | 166*94*50 | 0.32 | 60 | 176~264V |
40 box, a single carton packaging
We use standard shipping cardboard boxes to package your goods and take absolute safety measures. If you have packaging requirements, please let us know!
Q: How many Voltage you can supply?
A: 5V,12V,24V,30V,36V,(Depend on items).
Q: Do you have any MOQ limited for the order?
A:Our MOQ is 1000 pcs.
Q:Do you offer guarantee for the products?
A:Of course , we have 1 year product guarantee !
Q: How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q: How to deal with the faulty?
A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.