Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
1.Full range AC 180-260V Input 50/60HZ
2. Output : 400W 24V 16.6A (MAX)
3. 100% full load burn-in test
4. Protections: Short circuit / Overload / Over voltage / Over temperature
5. 12 months warranty
6. Working Temp: -20ºC~50ºC (-4 ºF ~ 122ºF)
7. Storage Temp: -40ºC~85ºC (-40 ºF ~ 185ºF)
8. Safety Compliance: FCC / CE
Package included:
1 x Power Supply (Power cord is NOT included.)
Model NO. | HY-400FA-12V | HY-400FA-24V | HY-400FAC-12V | HY-400FAC-24V | HY-400FA-II-12V | HY-400FA-II-24V | HY-400GB-24V | HY-400GB-12V | HY-600FA-12V |
Power | 400W | 400W | 400W | 400W | 400W | 400W | 400W | 400W | 600W |
Current | 33.3A | 16.6A | 33.3A | 16.7A | 33.3A | 16.6A | 16.6A | 33A | 50A |
Voltage | 12V | 24V | 12V | 24V | 12V | 24V | 24V | 12V | 12V |
Inlet stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±1.5% | ±1% | ±1.5% | ±1% | ±1.5% | ±1% | ±1% | ±1.5% | ±1.5% |
Wave and noise | 120mVp-p | 200mVp-p | 120mVp-p | 200mVp-p | 120mVp-p | 200mVp-p | 200mVp-p | 120mVp-p | 120mVp-p |
Voltage regulation range | 11.5-12.5V | 23.5-24.5V | 11.5-12.5V | 23.5-24.5V | 11.5-12.5V | 23.5-24.5V | 23.5-24.5V | 11.5-12.5V | 23.5-24.5V |
Size | 191*117*50mm | 179*109*51mm | 179*109*51mm | 204*117*50mm | 204*117*50mm | 217*118*50mm | |||
Working Temp | -20ºC-,50ºC | ||||||||
Storage Temp | -40ºC.85ºC | ||||||||
RisingTime | 2000ms,30ms@220Vac | ||||||||
Hold up Time | 10m5 @220Vae, at full load | ||||||||
Voltage Range | 176~264Vac200-380vdc | ||||||||
Frequency Range | 47~63HZ | ||||||||
Efficiency | 90% | ||||||||
AC Current | 1.94A@220Vac | ||||||||
Surge Current | 50A G220Vac Cold air dynamics | ||||||||
Leakage Current | <0.75mA@220Vac | ||||||||
Overload | 110%~150% of rated output power, protection mode; Hiccup mode, can be visually restored after removing abnormal conditions | ||||||||
Over voltage | 110%~135% of rated output power, Protection mode; Hiccup mode, Can be visually restored after removing abnormal conditions | ||||||||
Short circuit | Protection mode; Hiccup mode, can be visually restored after removing abnormal conditions,Can be short circuited for a long time | ||||||||
operation Temp | -20ºC-,50ºC | ||||||||
Operating Humidity | 20%~90%RH, No condensation | ||||||||
Storage Temp ,humidity | -40ºC.85ºC,10%~95%RH | ||||||||
Seismic Resistance | 100~500Hz,3G 10mins/cycle,60 mins each for the X Y and Z axes | ||||||||
Safety Standard | Complies with CE/FCC | ||||||||
Advantages | • Adopt high quality components | ||||||||
• Powerful, stable and reliable | |||||||||
• Built-in EMI filter circuit | |||||||||
• Dual-tube forward program | |||||||||
• Constant voltage and constant current output | |||||||||
• Intelligent overload prevention | |||||||||
• Semi-potted process | |||||||||
• Stronger ability to adapt to the environment | |||||||||
• Over-voltage, short-circuit, overload and temperature protection function | |||||||||
• High reliability -100% full load burn-in test. | |||||||||
Note: 1. Unless otherwise specified, all specification parameters are measured at an input of 220Vac, rated negative, and 25 "C ambient temperature . 2. Ripple and noise Runwu method: Use a 12 twisted pair cable, with terminals connected in parallel with 0.1UF and 47uF capacitors. and measure the ripple at a bandwidth of 20MHz. 3. Pressure accuracy: including setting error, linear adjustment , and negative adjustment rate. 4. Linear adjustment rate measurement method; Under a certain load, test from low input voltage to high input voltage. 5. Test method for load adjustment rate: from 0 to 100% rated load. 6. The startup time is measured in a cold start state, and rapid and frequent shutdowns may increase the startup time. |
Item | Output | Item size | Weight | PC/CTNS | ||||
5V | 12V | 24V | 30V | 36V | (MM) | (KG) | (PCS) | |
HY-400FB | 33.3A | 16.6A | 13.3A | 11.2A | 193*117*50 | 0.47 | 50 | |
HY-350FB | 70A | 193*117*50 | 0.49 | 50 | ||||
HY-400FA | 33.3A | 16.6A | 207*118*50 | 0.62 | 40 | |||
HY-400FAC | 33.3A | 16.7A | 207*118*50 | 0.62 | 40 | |||
HY-400FA-II | 33.3A | 24V | 179*109*51 | 0.54 | 40 | |||
HY-400GB | 33A | 16.6A | 204*117*50 | 0.47 | 40 | |||
HY-600FA | 50A | 25A | 217*118*50 | 0.85 | 30 | |||
HY-400FC | 26.6A | 13.5A | 191*117*50 | 0.42 | 50 | |||
HY-400FEC | 33.3A | 191*117*50 | 0.42 | 50 | ||||
HY-350FC | 70A | 191*117*50 | 0.42 | 50 | ||||
HY-400FC-II | 33.3A | 181*117*50 | 0.39 | 60 | ||||
HY-200FC | 16.7A | 166*94*50 | 0.32 | 60 | ||||
HY-150FC | 12A | 185*74*42 | 0.29 | 60 | ||||
HY-120FC | 10A | 145*74*42 | 0.23 | 80 | ||||
HY-60FC | 5A | 120*74*42 | 0.18 | 80 | ||||
HY-300TF | 25A | 191*117*50 | 0.42 | 60 | ||||
HY-300TBS | 25A | 191*117*50 | 0.42 | 60 | ||||
HY-300TBD | 25A | 166*94*50 | 0.32 | 60 |
40 box, a single carton packaging
We use standard shipping cardboard boxes to package your goods and take absolute safety measures. If you have packaging requirements, please let us know!
Q: How many Voltage you can supply?
A: 5V,12V,24V,30V,36V,(Depend on items).
Q: Do you have any MOQ limited for the order?
A:Our MOQ is 1000 pcs.
Q:Do you offer guarantee for the products?
A:Of course , we have 1 year product guarantee !
Q: How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.
Q: How to deal with the faulty?
A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.